text: |
While a ${/glossary/clock-tick:/term} is serviced, while the difference of
current counter value to the matching counter value is greater than the clock
tick counter interval, when the matching counter value was updated, the
matching couter value shall be incremented by the clock tick counter
interval.
type: requirement
|