# # $Id$ # # COPYRIGHT (c) 1989, 1990, 1991, 1992, 1993, 1994. # On-Line Applications Research Corporation (OAR). # All rights assigned to U.S. Government, 1994. # # This material may be reproduced by or for the U.S. Government pursuant # to the copyright license under the clause at DFARS 252.227-7013. This # notice must appear in all copies of this file and its derivatives. # This file describes the directives and concepts tested by this test set. test set name: test24 directives: ex_init, ex_start, t_create, t_start, tm_tick, i_return, t_ident, ev_receive concepts: a. This test is a cyclic version of test1. The times printed by each test should not skew as in test1 (see output section). b. Verifies system can create and start both the executive's system initialization and idle task. c. Verifies executive can swap between three application tasks at the same priority and the executive's internal idle task. d. Verifies can print strings to the CRT on port 2 of the mvme136 board using Print and Println in the board support package. e. Verifies interrupt handler can handler a task switch from an interrupt as specified with the i_return directive. f. Verifies executive initialization performed correctly. g. Verifies the executive trap handler except for the halt function. h. Verifies that a task can get the task identification number of itself. output: "TA1" is printed once every 5 seconds. "TA2" is printed once every 10 seconds. "TA3" is printed once every 15 seconds. The times printed should be multiples of 5 seconds for TA1, 10 seconds for TA2, and 15 seconds for TA3. If this does not happen, the calendar time does not correspond correctly to the number of ticks.