Patches against 1105 snapshot to add NTP server support to network
configuration/BOOTP.
|
|
|
|
|
|
|
|
| |
EPICS needs a synchronized time-of-day clock. This patch is the changes
needed to get NTP server information from a BOOTP server.
This patch also adds NTP server information to the network configuration
structure, too.
|
|
|
|
|
| |
I added __INSIDE_RTEMS_BSD_TCPIP_STACK__ that trips all the needed
macro definitions for a network driver.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1) Socket timeout field changed from `short' to `long'. This makes longer
timeouts possible. With a 1 kHz system clock the old system allowed
timeouts only up to a little over 30 seconds! This change is a
slightly cleaned-up version of the patch proposed by Ian Lance Taylor.
2) Major changes to BOOTP/DHCP reply handling. Now supports much of
RFC2132. These changes were done at the request of, and with the
assistance of, Erik Ivanenko.