diff options
Diffstat (limited to 'testsuites/samples')
-rw-r--r-- | testsuites/samples/ChangeLog | 5 | ||||
-rw-r--r-- | testsuites/samples/ticker/tasks.c | 4 |
2 files changed, 7 insertions, 2 deletions
diff --git a/testsuites/samples/ChangeLog b/testsuites/samples/ChangeLog index 6f1682ef45..44dc8fcf6e 100644 --- a/testsuites/samples/ChangeLog +++ b/testsuites/samples/ChangeLog @@ -1,5 +1,10 @@ 2009-08-10 Joel Sherrill <joel.sherrill@oarcorp.com> + * ticker/tasks.c: Convert calls to legacy routine rtems_clock_get( + RTEMS_CLOCK_GET_TOD, ..) to rtems_clock_get_tod(..). + +2009-08-10 Joel Sherrill <joel.sherrill@oarcorp.com> + * fileio/system.h: Switch to unified work area. 2009-06-11 Roxana Leontie <roxana.leontie@gmail.com> diff --git a/testsuites/samples/ticker/tasks.c b/testsuites/samples/ticker/tasks.c index d9c3791185..fabdbf7218 100644 --- a/testsuites/samples/ticker/tasks.c +++ b/testsuites/samples/ticker/tasks.c @@ -31,13 +31,13 @@ rtems_task Test_task( status = rtems_task_ident( RTEMS_SELF, RTEMS_SEARCH_ALL_NODES, &tid ); task_index = task_number( tid ); for ( ; ; ) { - status = rtems_clock_get( RTEMS_CLOCK_GET_TOD, &time ); + status = rtems_clock_get_tod( &time ); if ( time.second >= 35 ) { puts( "*** END OF CLOCK TICK TEST ***" ); rtems_test_exit( 0 ); } put_name( Task_name[ task_index ], FALSE ); - print_time( " - rtems_clock_get - ", &time, "\n" ); + print_time( " - rtems_clock_get_tod - ", &time, "\n" ); status = rtems_task_wake_after( task_index * 5 * get_ticks_per_second() ); } } |